Search results for “segmented electrodes

About 1 result in articles

Open Access Pub publishes peer-reviewed, free-to-read open-access articles. Showing articles matching segmented electrodes — open any to read the full text, or download the PDF or XML.

1 article

Reduction of Side Effects by Segmented Electrodes in Case of Subthalamic Nucleus Deep Brain Stimulation in Parkinson Disease: A Case Report.

Mar 2019 DOI 10.14302/issn.2470-5020.jnrt-19-2630
P. Schwarm FrankCorresponding author Department of Neurosurgery, Justus-Liebig University Giessen, Giessen, Germany

Patients suffering treatment resistant Parkinson´s disease (PD) are potential candidates for deep brain stimulation (DBS). Commonly most implanted electrodes have a cylindrical shape with quadripolar electrode contacts and generate a symmetrical stimulation field around the lead. To reduce side effects through activation of neighboring fibers a new electrode design with segmented contacts was developed and enables a better adaption of the field of stimulation as well as a multi-target stimulation to improve therapeutic benefits. We report about a 51-year-old male patient with a 15-year history of treatment-refractory PD, who was implanted with bilateral segmented electrodes in the subthalamic nucleus (STN) with St. Jude Medical Infinity™ DBS System (Abbott/St. Jude Medical, Saint Paul, Minnesota, USA). Despite a clear mood-enhancing effect, stimulation with ring electrodes caused motor side effects including rigor and speech disorder. With segmented electrodes an effective and gentle stimulation was achieved. The stimulation of the anterior segments in the central position of the electrode in the STN showed no side-effects and allowed a reduction of initial symptoms in an low stimulation amplitude. Despite precise preoperatively planning and intraoperative trial stimulation, side effects of STN stimulation are very common. The application of segmented electrodes permits more options to reduce side effects rather than using ring electrodes. Studies with larger sample sizes are needed to establish the optional DBS electrode.

Frequently asked questions

Are these articles peer-reviewed?
Yes. Articles published at Open Access Pub go through single-blind peer review (double-blind on request) under an editorial board before publication.
Are the articles free to read?
Yes. Every article is open access — read the full text online for free and download the PDF or XML, with no paywall or subscription.
How do I cite an article?
Use the DOI shown on each result and on the article page; it is the permanent, citable link to the article.
How do I read or download an article?
Click "Read full text" to open the article HTML, or use the PDF / XML buttons on each card to download it.